GlowCertificate of Analysis

  • Tested by Accumark Labs
  • Report PT3S-35FM
  • Conforms to the lab's specification
Accumark LabsCertificate of Analysis · Anaheim, CaliforniaReport PT3S-35FM

Glow

Lot 457090 · HPLC purity · Identity · Quantity (mg per vial)

Full report on Accumark Labs (opens in new tab)
Glow vial
Glow results reported by Accumark Labs
TestResultStatus
Purity (HPLC)
  • 99.93%
spec > 98.0%Conforms
Conforms
Identity
  • GHK-Cu, BPC-157, TB500 (17-23 Fragment)
Conforms
Conforms
GHK‑Cu
  • 58.661 mg
purity 99.917%Measured
Measured
BPC‑157
  • 12.993 mg
purity 99.905%Measured
Measured
TB500 (17‑23 Fragment)
  • 14.201 mg
purity 99.992%Measured
Measured

Figures copied exactly from Accumark Labs's own report. Open it to check every line.

HPLC chromatogram

0510152025Retention time (min)
Chromatogram as published by Accumark Labs for report PT3S-35FM. Purity on this certificate is the lab's figure; it excludes the unretained solvent peak near the start of the run.

How to read this Glow certificate

A Certificate of Analysis is the testing lab's record of what it measured in a sample. Here is what each line on this certificate means:

  • Identity: GHK-Cu, BPC-157, TB500 (17-23 Fragment) — Conforms. The lab confirmed the sample is the named compound.
  • GHK-Cu — measured content: 58.661 mg (purity 99.917%). The amount of the compound the lab measured in the vial. Several values mean several vials were tested.
  • BPC-157 — measured content: 12.993 mg (purity 99.905%). The amount of the compound the lab measured in the vial. Several values mean several vials were tested.
  • TB500 (17-23 Fragment) — measured content: 14.201 mg (purity 99.992%). The amount of the compound the lab measured in the vial. Several values mean several vials were tested.
  • Purity (HPLC): 99.93% — Conforms (spec > 98.0%). HPLC separates the sample into its components; purity is the share of the main compound. Where several values are listed, each is a separate vial.

To confirm these figures, open the Accumark Labs report linked on this page and check that its report ID is PT3S-35FM.

HPLC testing methodology

High-Performance Liquid Chromatography (HPLC) is the standard analytical technique used to verify peptide purity. Peptide labs typically run reverse-phase HPLC with UV detection. The chromatogram displays retention time on the x-axis and UV absorbance on the y-axis. The area under each peak corresponds to compound quantity. Purity is calculated as the target peak area divided by total peak area, expressed as a percentage. A purity of 98% or above is the usual research-grade threshold.

Storage & handling

Research peptides should be stored lyophilized (freeze-dried) at -20°C or below until ready for use. Avoid repeated freeze-thaw cycles. Upon reconstitution, store at 4°C and use within 30 days. Keep away from direct light and moisture. All handling should be performed under sterile research conditions by qualified personnel following applicable laboratory safety protocols.

Intended use

Glow is supplied for laboratory research purposes only. Not intended for human or veterinary use, diagnostic procedures, or clinical applications.