AOD-9604Certificate of Analysis

AOD-9604 (lab sample AM20260925-02) was tested at 99.022% HPLC purity by Accumark Labs (Anaheim, California), analysis completed Oct 1, 2026; report SDWT-ZBGT is verifiable at accumarklabs.com.

  • Tested by Accumark Labs
  • Report SDWT-ZBGT
  • Conforms to the lab's specification
Purity (HPLC)
99.022%spec > 98.0%Conforms
Quantity
9.807 mg
Analysis completed
Oct 1, 2026

HPLC chromatogram

05101520Retention time (min)
Chromatogram redrawn from Accumark Labs' data for report SDWT-ZBGT. Purity on this certificate is the lab's figure; it excludes the unretained solvent peak near the start of the run. View the original report on Accumark Labs (opens in new tab)
Accumark LabsCertificate of Analysis · Anaheim, CaliforniaReport SDWT-ZBGT

AOD-9604

HPLC purity · Identity · Quantity (mg per vial)

Full report on Accumark Labs (opens in new tab)
AOD-9604 vial
AOD-9604 results reported by Accumark Labs
TestResultStatus
Purity (HPLC)
  • 99.022%
spec > 98.0%Conforms
Conforms
Identity
  • AOD-9604
Conforms
Conforms
Quantity
  • 9.807 mg
Measured
Measured
Report ID
SDWT-ZBGT
Lab sample ID
AM20260925-02
Sample received
Sep 24, 2026
Analysis completed
Oct 1, 2026
Laboratory
Accumark Labs, Anaheim, California
Vials tested
1
Mass spectrometry
Not reported on this certificate

Figures copied exactly from Accumark Labs' own report. Open it to check every line.

Permanent page for report SDWT-ZBGT — stays at this address after a newer lot replaces it.

What the values on this report mean

HPLC purity 99.022%: in the lab's chromatogram, 99.022% of the detected peak area belongs to the AOD-9604 peak and the remaining 0.978% to other components the method detected.

Accumark Labs printed a purity specification of > 98.0% and marked the result "Conforms".

Measured content of AOD-9604: the amount Accumark Labs quantified in the vial it received (9.807 mg). It is a measurement of this sample, not a label figure.

Identity: AOD-9604, "Conforms". Accumark Labs' identity test matched the sample to AOD-9604.

Mass spectrometry is not reported on this certificate; the molecular weight in the compound identity section is PubChem reference data, not a measurement of this lot.

How to verify report SDWT-ZBGT

  1. Open the report from the "Full report" link. It opens on accumarklabs.com, Accumark Labs' own site, not a file hosted by us.
  2. Check that the lab's page shows report SDWT-ZBGT.
  3. Check the lot: AM20260925-02.
  4. Check the analysis completion date: Oct 1, 2026.
  5. Compare the figures with this certificate: HPLC purity 99.022%; AOD-9604 9.807 mg.

How to verify an Accumark Labs report, step by step

HPLC testing methodology

Purity comes from reverse-phase HPLC with UV detection: the target peak's share of total detected area, measured per vial. What HPLC shows and how to read it.

Storage & handling

Store lyophilized at −20 °C or below; after reconstitution keep at 4 °C and use within 30 days. Full handling and storage guidance.

Intended use

AOD-9604 is supplied for laboratory research purposes only. Not intended for human or veterinary use, diagnostic procedures, or clinical applications.

Compound identity reference

Reference identity data for AOD-9604, compiled by Peptide Hackers from PubChem — not part of the lab's certificate above, which reports only what the lab measured in this lot.