Figures copied exactly from Janoshik Analytical's own report. Open it to check every line.
What the values on this report mean
HPLC purity was measured separately on each vial: vial 1 99.777%, vial 2 99.835%, vial 3 99.798%. Across the 3 vials the results range from 99.777% to 99.835%, a spread of 0.058 percentage points.
Janoshik Analytical printed no purity specification or pass/fail verdict on this report; the figure is a measurement only.
Measured content of GHK-Cu: the amount Janoshik Analytical quantified in the 3 vials it received (56.09 mg, 57.17 mg, 56.31 mg). It is a measurement of this sample, not a label figure.
This report carries no identity result: Janoshik Analytical reports measured content and purity only.
Mass spectrometry is not reported on this certificate.
How to verify report #92374
Open the report from the "Full report" link. It opens on verify.janoshik.com, Janoshik Analytical's own site, not a file hosted by us.
Check that the lab's page shows report #92374.
The lab's report prints no lot for this sample, so none is shown here either.
Compare the figures with this certificate: HPLC purity 99.777%, 99.835%, 99.798%; GHK-Cu 56.09 mg, 57.17 mg, 56.31 mg.
High-Performance Liquid Chromatography (HPLC) is the standard analytical technique used to verify peptide purity. Peptide labs typically run reverse-phase HPLC with UV detection. The chromatogram displays retention time on the x-axis and UV absorbance on the y-axis. The area under each peak corresponds to compound quantity. Purity is calculated as the target peak area divided by total peak area, expressed as a percentage. A purity of 98% or above is the usual research-grade threshold.
Storage & handling
Research peptides should be stored lyophilized (freeze-dried) at -20°C or below until ready for use. Avoid repeated freeze-thaw cycles. Upon reconstitution, store at 4°C and use within 30 days. Keep away from direct light and moisture. All handling should be performed under sterile research conditions by qualified personnel following applicable laboratory safety protocols.
Intended use
BPC-157 + TB-500 is supplied for laboratory research purposes only. Not intended for human or veterinary use, diagnostic procedures, or clinical applications.