Glow (lot 457090) was tested at 99.93% HPLC purity by Accumark Labs (Anaheim, California), analysis completed Sep 28, 2026; report PT3S-35FM is verifiable at accumarklabs.com.
Chromatogram redrawn from Accumark Labs' data for report PT3S-35FM. Purity on this certificate is the lab's figure; it excludes the unretained solvent peak near the start of the run. View the original report on Accumark Labs (opens in new tab)
Accumark LabsCertificate of Analysis · Anaheim, CaliforniaReport PT3S-35FM
HPLC purity 99.93%: in the lab's chromatogram, 99.93% of the detected peak area belongs to the Glow peak and the remaining 0.07% to other components the method detected.
Accumark Labs printed a purity specification of > 98.0% and marked the result "Conforms".
Measured content of GHK-Cu: the amount Accumark Labs quantified in the vial it received (58.661 mg), with a per-compound HPLC purity of 99.917%. It is a measurement of this sample, not a label figure.
Measured content of BPC-157: the amount Accumark Labs quantified in the vial it received (12.993 mg), with a per-compound HPLC purity of 99.905%. It is a measurement of this sample, not a label figure.
Measured content of TB500 (17-23 Fragment): the amount Accumark Labs quantified in the vial it received (14.201 mg), with a per-compound HPLC purity of 99.992%. It is a measurement of this sample, not a label figure.
Identity: GHK-Cu, BPC-157, TB500 (17-23 Fragment), "Conforms". Accumark Labs' identity test matched the sample to GHK-Cu, BPC-157, TB500 (17-23 Fragment).
Mass spectrometry is not reported on this certificate.
How to verify report PT3S-35FM
Open the report from the "Full report" link. It opens on accumarklabs.com, Accumark Labs' own site, not a file hosted by us.
Check that the lab's page shows report PT3S-35FM.
Check the lot: 457090.
Check the analysis completion date: Sep 28, 2026.
Compare the figures with this certificate: HPLC purity 99.93%; GHK-Cu 58.661 mg; BPC-157 12.993 mg; TB500 (17-23 Fragment) 14.201 mg.
Purity comes from reverse-phase HPLC with UV detection: the target peak's share of total detected area, measured per vial. What HPLC shows and how to read it.