BPC-157Certificate of Analysis

BPC-157 (lot 708364) was tested at 99.846% HPLC purity by Accumark Labs (Anaheim, California), analysis completed Sep 28, 2026; report VCSG-286G is verifiable at accumarklabs.com.

  • Tested by Accumark Labs
  • Report VCSG-286G
  • Conforms to the lab's specification
Purity (HPLC)
99.846%spec > 98.0%Conforms
Quantity
11.12 mg
Analysis completed
Sep 28, 2026

HPLC chromatogram

0510152025Retention time (min)
Chromatogram redrawn from Accumark Labs' data for report VCSG-286G. Purity on this certificate is the lab's figure; it excludes the unretained solvent peak near the start of the run. View the original report on Accumark Labs (opens in new tab)
Accumark LabsCertificate of Analysis · Anaheim, CaliforniaReport VCSG-286G

BPC-157

HPLC purity · Identity · Quantity (mg per vial)

Full report on Accumark Labs (opens in new tab)
BPC-157 vial
BPC-157 results reported by Accumark Labs
TestResultStatus
Purity (HPLC)
  • 99.846%
spec > 98.0%Conforms
Conforms
Identity
  • BPC-157
Conforms
Conforms
Quantity
  • 11.12 mg
Measured
Measured
Report ID
VCSG-286G
Batch
708364
Sample received
Sep 24, 2026
Analysis completed
Sep 28, 2026
Laboratory
Accumark Labs, Anaheim, California
Vials tested
1
Mass spectrometry
Not reported on this certificate

Figures copied exactly from Accumark Labs' own report. Open it to check every line.

Permanent page for report VCSG-286G — stays at this address after a newer lot replaces it.

What the values on this report mean

HPLC purity 99.846%: in the lab's chromatogram, 99.846% of the detected peak area belongs to the BPC-157 peak and the remaining 0.154% to other components the method detected.

Accumark Labs printed a purity specification of > 98.0% and marked the result "Conforms".

Measured content of BPC-157: the amount Accumark Labs quantified in the vial it received (11.12 mg). It is a measurement of this sample, not a label figure.

Identity: BPC-157, "Conforms". Accumark Labs' identity test matched the sample to BPC-157.

Mass spectrometry is not reported on this certificate; the molecular weight in the compound identity section is PubChem reference data, not a measurement of this lot.

How to verify report VCSG-286G

  1. Open the report from the "Full report" link. It opens on accumarklabs.com, Accumark Labs' own site, not a file hosted by us.
  2. Check that the lab's page shows report VCSG-286G.
  3. Check the lot: 708364.
  4. Check the analysis completion date: Sep 28, 2026.
  5. Compare the figures with this certificate: HPLC purity 99.846%; BPC-157 11.12 mg.

How to verify an Accumark Labs report, step by step

HPLC testing methodology

Purity comes from reverse-phase HPLC with UV detection: the target peak's share of total detected area, measured per vial. What HPLC shows and how to read it.

Storage & handling

Store lyophilized at −20 °C or below; after reconstitution keep at 4 °C and use within 30 days. Full handling and storage guidance.

Intended use

BPC-157 is supplied for laboratory research purposes only. Not intended for human or veterinary use, diagnostic procedures, or clinical applications.

Compound identity reference

Reference identity data for BPC-157, compiled by Peptide Hackers from PubChem — not part of the lab's certificate above, which reports only what the lab measured in this lot.