EpithalonCertificate of Analysis

Epithalon (lot 4003) was tested at 99.039% HPLC purity by Accumark Labs (Anaheim, California), analysis completed Sep 28, 2026; report TV7W-QKZJ is verifiable at accumarklabs.com.

  • Tested by Accumark Labs
  • Report TV7W-QKZJ
  • Conforms to the lab's specification
Purity (HPLC)
99.039%spec ≥ 98 %Conforms
Quantity
9.698 mg
Analysis completed
Sep 28, 2026

HPLC chromatogram

0510152025Retention time (min)
Chromatogram redrawn from Accumark Labs' data for report TV7W-QKZJ. Purity on this certificate is the lab's figure; it excludes the unretained solvent peak near the start of the run. View the original report on Accumark Labs (opens in new tab)
Accumark LabsCertificate of Analysis · Anaheim, CaliforniaReport TV7W-QKZJ

Epithalon

HPLC purity · Identity · Quantity (mg per vial)

Full report on Accumark Labs (opens in new tab)
Epithalon vial
Epithalon results reported by Accumark Labs
TestResultStatus
Purity (HPLC)
  • 99.039%
spec ≥ 98 %Conforms
Conforms
Identity
  • Epitalon
Conforms
Conforms
Quantity
  • 9.698 mg
Measured
Measured
Report ID
TV7W-QKZJ
Batch
4003
Sample received
Sep 24, 2026
Analysis completed
Sep 28, 2026
Laboratory
Accumark Labs, Anaheim, California
Vials tested
1
Mass spectrometry
Not reported on this certificate

Figures copied exactly from Accumark Labs' own report. Open it to check every line.

Permanent page for report TV7W-QKZJ — stays at this address after a newer lot replaces it.

What the values on this report mean

HPLC purity 99.039%: in the lab's chromatogram, 99.039% of the detected peak area belongs to the Epithalon peak and the remaining 0.961% to other components the method detected.

Accumark Labs printed a purity specification of ≥ 98 % and marked the result "Conforms".

Measured content of Epithalon: the amount Accumark Labs quantified in the vial it received (9.698 mg). It is a measurement of this sample, not a label figure.

Identity: Epitalon, "Conforms". Accumark Labs' identity test matched the sample to Epitalon.

Mass spectrometry is not reported on this certificate; the molecular weight in the compound identity section is PubChem reference data, not a measurement of this lot.

How to verify report TV7W-QKZJ

  1. Open the report from the "Full report" link. It opens on accumarklabs.com, Accumark Labs' own site, not a file hosted by us.
  2. Check that the lab's page shows report TV7W-QKZJ.
  3. Check the lot: 4003.
  4. Check the analysis completion date: Sep 28, 2026.
  5. Compare the figures with this certificate: HPLC purity 99.039%; Epithalon 9.698 mg.

How to verify an Accumark Labs report, step by step

HPLC testing methodology

Purity comes from reverse-phase HPLC with UV detection: the target peak's share of total detected area, measured per vial. What HPLC shows and how to read it.

Storage & handling

Store lyophilized at −20 °C or below; after reconstitution keep at 4 °C and use within 30 days. Full handling and storage guidance.

Intended use

Epithalon is supplied for laboratory research purposes only. Not intended for human or veterinary use, diagnostic procedures, or clinical applications.

Compound identity reference

Reference identity data for Epithalon, compiled by Peptide Hackers from PubChem — not part of the lab's certificate above, which reports only what the lab measured in this lot.