SemaglutideCertificate of Analysis

Semaglutide (lot 7832) was tested at 99.93% HPLC purity by Accumark Labs (Anaheim, California), analysis completed Sep 28, 2026; report 7B73-DE8D is verifiable at accumarklabs.com.

  • Tested by Accumark Labs
  • Report 7B73-DE8D
  • Conforms to the lab's specification
Purity (HPLC)
99.93%spec ≥ 98 %Conforms
Quantity
37.822 mg
Analysis completed
Sep 28, 2026

HPLC chromatogram

05101520Retention time (min)
Chromatogram redrawn from Accumark Labs' data for report 7B73-DE8D. Purity on this certificate is the lab's figure; it excludes the unretained solvent peak near the start of the run. View the original report on Accumark Labs (opens in new tab)
Accumark LabsCertificate of Analysis · Anaheim, CaliforniaReport 7B73-DE8D

Semaglutide

HPLC purity · Identity · Quantity (mg per vial)

Full report on Accumark Labs (opens in new tab)
Semaglutide vial
Semaglutide results reported by Accumark Labs
TestResultStatus
Purity (HPLC)
  • 99.93%
spec ≥ 98 %Conforms
Conforms
Identity
  • Semaglutide
Conforms
Conforms
Quantity
  • 37.822 mg
Measured
Measured
Report ID
7B73-DE8D
Batch
7832
Sample received
Sep 24, 2026
Analysis completed
Sep 28, 2026
Laboratory
Accumark Labs, Anaheim, California
Vials tested
1
Mass spectrometry
Not reported on this certificate

Figures copied exactly from Accumark Labs' own report. Open it to check every line.

Permanent page for report 7B73-DE8D — stays at this address after a newer lot replaces it.

What the values on this report mean

HPLC purity 99.93%: in the lab's chromatogram, 99.93% of the detected peak area belongs to the Semaglutide peak and the remaining 0.07% to other components the method detected.

Accumark Labs printed a purity specification of ≥ 98 % and marked the result "Conforms".

Measured content of Semaglutide: the amount Accumark Labs quantified in the vial it received (37.822 mg). It is a measurement of this sample, not a label figure.

Identity: Semaglutide, "Conforms". Accumark Labs' identity test matched the sample to Semaglutide.

Mass spectrometry is not reported on this certificate; the molecular weight in the compound identity section is PubChem reference data, not a measurement of this lot.

How to verify report 7B73-DE8D

  1. Open the report from the "Full report" link. It opens on accumarklabs.com, Accumark Labs' own site, not a file hosted by us.
  2. Check that the lab's page shows report 7B73-DE8D.
  3. Check the lot: 7832.
  4. Check the analysis completion date: Sep 28, 2026.
  5. Compare the figures with this certificate: HPLC purity 99.93%; Semaglutide 37.822 mg.

How to verify an Accumark Labs report, step by step

HPLC testing methodology

Purity comes from reverse-phase HPLC with UV detection: the target peak's share of total detected area, measured per vial. What HPLC shows and how to read it.

Storage & handling

Store lyophilized at −20 °C or below; after reconstitution keep at 4 °C and use within 30 days. Full handling and storage guidance.

Intended use

Semaglutide is supplied for laboratory research purposes only. Not intended for human or veterinary use, diagnostic procedures, or clinical applications.

Compound identity reference

Reference identity data for Semaglutide, compiled by Peptide Hackers from PubChem — not part of the lab's certificate above, which reports only what the lab measured in this lot.